This is an independent, unofficial enthusiast run site dedicated to Weber Grill owners that share the same passion as we do. Since the glow plugs are not readily available in stores yet and maybe never will be, I keep a couple of glow plugs and put them on the shelf. Lets hope these new ones make it a solid cooker. I think/hope it will work great. I assume this is a time\usage based message. Hmmm. Beautiful but crisp day this morning here in Northern Illinois with an outside temperature of 40 degrees so decided to install the new glow plug. I received the augur assembly replacement kit from Weber today, put it in and tested the grill. However, in this application they're being left energized for a while until the smoker starts up. You’ve probably already perused other reviews of Weber’s SmokeFire pellet grill, which hit stores early this year. As shown in the picture the new plug showed 9.3 OHMs while all 3 of the old plugs showed zero, Ah ha! If this does not help, initiate a factory reset via the Menu settings. As shown in the picture the new plug showed 9.3 OHMs while all 3 of the old plugs showed zero. Installed the new glow plug in the new bracket assembly making sure there was a tight fit and the ground was properly seated but did not use a radiator hose clamp just because I shouldn’t have to; removed all the old pellets and filled with fresh Weber pellets; plugged directly into the outlet with no extension cord; and finally made sure app, software and firmware were all up-to-date. Any trademarks, service marks or trade names referred to on this website remain the full property of their respective owners. Carefully remove the glow plug assembly by removing the bracket screw that holds it in place and sliding the assembly out from the grill. I'm still so perplexed that some people have no problems and others continue to have problem after problem but what I do know is that I've cooked some killer BBQ when it runs right. I'm also looking for this. Hot. Weber did just release a new version so maybe that will correct the problem. Weber did just release a new version so maybe that will correct the problem. Submit a request. The content may contain affiliate links of Ebay and Amazon – in return our website earns a small commission for referral. Weber sent me a placement glow plug, not instructions on how to replace it. Join. I am reluctant to replace the glow since I have not had any issues with it. Not knowing how it is connected... i have to ask if the plug could possibly have a weak connection or heat sink. I would not recommend that either. For a better experience, please enable JavaScript in your browser before proceeding. You must log in or register to reply here. It may not display this or other websites correctly. Not a lot of large slow roasting besides the turkey. From the rear of your SmokeFire grill, remove the rear access panel by removing four screws. This page contains ads and links that earn commissions for TVWBB.The Virtual Weber Bulletin Board is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com. A GUIDE TO SMOKING - Weber SmokeFire - Assembly Guide – Weber Grills A beginner's guide to smoking – Weber Weber Smokey Mountain Review & Buying Guide 2020 Ultimate Guide to Smoking with Wood - King of the Coals Weber's Smoke: A Guide to Smoke Cooking for Everyone and ... Weber's Smoke: A Guide to Smoking ROCKS! It would seem that it still being a relatively new grill, the glow plugs already wearing out would be a bit of a concern. The difference between the 1st and 2nd generation would be that the 2nd generation has our welded pellet chute, a hopper slide, and the most current versions of software and firmware – all of the same updates we have already provided to SmokeFire owners over the past several months. User account menu. That said, if it scared you when you did it then maybe it's not for you and I don't mean that as a put down. If the glow plug is operating correctly, it will start to glow in color as it heats. If the smoker had a misfire and didn't ignite, my hunch is the glow plug would run even longer. Here’s a step by step video on how I replaced the auger and chute assembly on my EX6. Loading content... Why am I seeing more smoke or a larger flame when my grill is re-igniting? 3. I do have 2 spares on hand, thanks Weber! I was very happy with the response I received from them. Hopefully I won't need to try it again since I got an email this afternoon that two of the new model glow plugs shipped today. How is the glow plug replaced on the Weber SmokeFire grill? I’m totally gun shy right now so did everything by the manual. Smoked … She has never replaced anything but a grate that the welds broke on. We can plug this equation into the SmokeFire motherboard. I'm sure hoping that they work a lot better than the old model for me. 6. Helpful. I decided to buy a multi-meter and test them so I know if anything changes after using it. Site Help and Suggestions . Create a Weber-ID My account Profile My Grills My Orders My Addresses Search Go to Search Results. Bosch 80010/0250201032 Duraterm Glow Plug Product Description & Features: Bosch patented Duraterm technology enables the glow plug to reach higher temperatures more quickly for fast… Warning: Do not touch the glow plug to check if it is hot. I can't believe it's safe and I even asked a Weber support person who said besides the safety issue it could void the warranty if something is damaged. Register Grill; Store Finder; Find HELP; Shop eGift Cards; Direct Financing Now Available English Log in | Weber-ID. None the less, it failed and by looking at the glow plug, it looks like a cheap off-brand. The glow plug didn’t ignite. Is it hard to change the plug? I am now getting a message that I need to change the glow plug soon. JavaScript is disabled. 5. Was this article helpful? I tend to cook more burgers, chops and chicken. 5. 4) Called customer service and feel Weber is having a lot of issues with the SmokeFire. Weber SmokeFire Forum. Additionally, I need to buy some spare fuses. I wish I had a multi-meter to test them but not going to buy one just for that purpose. Help! Soon after the Weber SmokeFire hardwood pellet barbecue first launched in North America at the start of 2020, there were reports of problems. 7. The Virtual Weber Bulletin Board is an unofficial Weber product fan site and is not affiliated with Weber-Stephen Products LLC. Thank you for reaching out to Weber, and for your interest in our 2nd Generation of SmokeFires. I didn’t separate the chute and just install the new auger. For the glow plug to fire properly on your SmokeFire grill, you will need to ensure that the glow plug is connected properly and that the grounding wire is touching the glow plug itself. So far so good.#weber #smokefire#smokefire repair If the glow plug … Difficulty Pairing with Weber SmokeFire Grill Loading content... How is the glow plug replaced on the Weber SmokeFire grill? Weber has been great in support of the smokefire owners honestly. Weber SmokeFire EX4 SillyRabbit said: I had to replace my controller recently due to a bad temp probe port. I read that the problem may be that the glow plug doesn't fit tightly in the bracket assembly and that you should use a radiator hose clamp to secure it and always test the glow plug with a multi-meter to make sure the plug is bad. I tried it once and it did work but I got huge temperature swings before it finally settled down. Sears and smokes. Official Weber Website. Some things just don't work for some people. Grounding Wire Not Connected. Posted by 7 days ago. 1 month ago. It may not display this or other websites correctly. What to do? Prone to grease fires: The design of this grill allows for all grease to drip into the bottom of the smoke chamber and diverts that grease toward the center of the grill to the firebox. Thanks for the encouragement. Press question mark to learn the rest of the keyboard shortcuts . An Apple Sauce Recipe Along With A Vinegar Sauce For Pulled Pork, New app version 1.1.1 for both Android and IOS. I do wonder if some sfs got a part or two out of variance, maybe even software, and that does the glow plug in. There were cases where this seal was peeling with significant use, which would lead to jams. Turns out the original bolt is 1/4"-20 so, instead of prepping for my coaches meeting this evening, I went out and picked up some cutting oil and rethreaded my handle so it now fits nicely with the original mounting hardware (no holes to plug). And you probably left those reviews thinking the SmokeFire sorta sucks. Hot New Top Rising. Feb 20, 2020 … You're putting the torch flame in an area that gets extremely hot when you're running at 600 pit temp That's corporate CYA talk. Weber SmokeFire Pellet Grill pulled pork over night cook. There's almost zero chance of burning yourself unless you get crazy with the torch. Fired it up again with same setup and it reached 600 in 11 minutes and 22 seconds. Jerry, I get scared on tall ladders and I flew Navy aircraft for 25 years. share. Believe me I have no idea what I'm doing but I read somewhere that a new plug should read around 10.9 OHMs and a used plug should read around 6 OHM. Reactions: Brian Vallotton. Visually they look exactly the same but the # on the new plug is TY24V2040D while the old is TY24V1947. I turned it on for the initial burn. Pairing with the Weber SmokeFire Grill ; Difficulty Pairing with Weber SmokeFire Grill If you are experiencing issues pairing to your SmokeFire via Bluetooth®, power off the barbecue via the physical switch for 30 seconds and power it back on. Here we have a 24 volt DC power feed with the standard 10 Ohm Weber glow plug. card. A few days later I received a new augur, motor, and augur feed hopper, which took over an hour to replace. Sort by. Perfect. Thankfully, Weber has rectified the biggest issues that some owners have had so that all new models of its SmokeFire EX4 should now work as advertised. You will get the temp swings but it settles down reasonably fast unless you fill the burn pot with fresh pellets. Unplug the glow plug assembly wire by pinching and pulling the quick disconnect plug. By the time this Weber support person has finished, I'll have an entirely new BBQ made out replacement parts . The SmokeFire has the following issues: 1. I called Weber and the sent me the replacement glow plug and several other parts that I may need. Learn More Discover the SmokeFire Difference Bucket-free grease & ash removal . hide. Mine is 6 years old and I don’t have a spare. Weber made claims about occasional cleaning and that that cleaning would only take a few minutes. The plugs are covered under warranty and if you ask nicely the support rep will usually send you 2. I would not recommend it but have lighted my house heater when the glow plug went bad with a lighter on a very cold night. Carefully remove the glow plug assembly by removing the bracket screw that holds it in place and sliding the assembly out from the grill. Wonder how it knows the history since the controller was just replaced??? I have an EX6 . This is a long video where we experience and evaluate the cooker together. 4. 4 comments. Weber have re-designed the Auger housing; it is now a singular, welded piece that no longer features that same grommet. I read that the problem may be that the glow plug doesn't fit tightly in the bracket assembly and that you should use a radiator hose clamp to secure it and always test the glow plug with a multi-meter to make sure the plug is bad. 2 people found this helpful. I had to replace my controller recently due to a bad temp probe port. Press J to jump to the feed. Took care of the issues I was having with my Smokefire. I bent the contact more and then forced the glow plug in further than originally done. Sorry to keep dragging this post on and on but I really want to get my SF back up and running and start smoking great BBQ again. If the glow plug is operating correctly: Reinstall the heat baffle, heat diffuser, Flavorizer bars and cooking grates inside the cookbox. I am not sure I will like the look, but truthfully I wanted it more for testing the lift on the lid rather than looks. Some patience was required during the peak of covid and trying to get through, but they have always been responsive and easy to deal with. Sie sind hier: Startseite » Grill Zubehör » Weber Ersatzteile / Grillroste » Zünder Glow Plug für SmokeFire EX4 & EX6 Weber Pellegrill Zubehör Zünder Glow Plug für SmokeFire EX4 & EX6 Hot New Top. All I can tell you is that I've gone through 3 glow plugs in 10 weeks. I've got a new glow plug coming which I've been asked to test. save. 67% Upvoted. Now that I have had a couple months to cook with the grill I found that it makes very tasty food. Glow Plugs typically don't run for a long duration of time in an automotive application. What was advertised was that it would be easy to operate and maintain. Weber SmokeFire Forum. Comment … Log in New to this site? SmokeFire’s internal cleaning system keeps ash and grease in an easy-clean drawer. SmokeFire - Owner's Manual; Helpful Tips When Using the SmokeFire Grill; Where is my serial number? I cannot see how you can damage anything lighting the pellets with a torch. It sounds like your auger wasn't filled with pellets on the first try but that's great news Jerry. EX4 1 day ago. You are using an out of date browser. Rising. Some owners complained about unreliable temperature consistency, technical issues with the app, and difficulties with hardwood pellets jamming in … 24 volts / 10 Ohm's = 2.4 amps of load. Joined Dec 28, 2020 Messages 2 Reaction score 3 Points 3 Location Ohio Grill Smoke Fire EX6 I received my Smoke Fire on 12/23/20 prebuilt. Made better contact with the glow plug and it worked perfectly. I am reluctant to replace the glow since I have not had any issues with it. It worked great. Maybe the old number ones had issues. I'm just worried that I will change it and then start having problems, but also don't want to have it die during a cook. I made sure all of the glow plugs were properly seated in the bracket and the last one I used a small radiator hose clamp to help hold the ground against the plug but it didn't make any difference. I am now getting a message that I need to change the glow plug soon. 5. Log In Sign Up. Glow Plug Not Seated Properly. Wonder how it knows the history since the controller was just replaced??? One final update. Personally though I don't think it's going to fix anything as the glow plug has no issues firing under normal cooking modes. I do have 2 … Last edited: Feb 20, 2020. 600° is the magic number. report. The representative also was convinced the problem was caused by the augur not feeding correctly. Software Updates for the Weber SmokeFire Grill; How is the glow plug replaced on the Weber SmokeFire … View entire discussion ( 1 comments) More posts from the smokefire community. 7. I've been without a glow plug for 3 weeks now because they were out of stock and then Weber ordered the wrong part. My daughter has a Traeger that's about 10 years old that they use a lot. This is suggested on another site and they even have videos on how to do it. Carefully remove the glow plug assembly by removing the bracket screw that holds it in place and sliding the assembly out from the barbecue. Good luck and happy smoking!!! 4. For a better experience, please enable JavaScript in your browser before proceeding. Read more. 6. SmokeFire grills are made in the USA, incorporating globally sourced component parts. From the rear of your SmokeFire grill, remove the rear access panel by removing four screws. I'm attaching a picture of the proper connection. They can last a few months or many years. Has anyone used a blow torch or other method to light the SF when the glow plug doesn't fire? Some of the initial issues that customers were facing in other markets was around a small seal that was within the auger (also referred to as a grommet). Maybe someone can help me out here. Remove the glow plug from the glow plug assembly by pulling it out … That being said the new chute and finger guard removal is important. Posted by 1 day ago. Roll smoke. The Camp Chef and many others use a hot rod. Unplug the glow plug assembly wire by pinching and pulling the quick disconnect plug. Sub dedicated to Weber smokefire series pellet cookers r/ smokefire. I decided to buy a multi-meter and test them so I know if anything changes after using it. I assume this is a time\usage based message. I have had very few issues overall. After reading some of the comments here I called and asked her how many glow plugs have they gone through, she said "what's a glow plug". I've done it and would do it again if needed. Get some smoke on it. Maybe rin the test tonight then smoke the Turkey is done or you have to move it to another device. The plugs are covered under warranty and if you ask nicely the support rep will usually send … Lets use the .5 Ohm Ford plug in the SmokeFire: 24 volts / .5 Ohm's = 48 amps of load = blown non-replaceable 5 amp fuse on the motherboard and a dead SmokeFire. Have more questions? Unplug the glow plug assembly wire by pinching and pulling the quick disconnect plug. Weber Connect links up with the SmokeFire via Bluetooth and/or wifi, and you’ll want to get this set up as soon as your SmokeFire is built. level 1. installing it is part of the first time assembly. WeberPelletGrills.com is not affiliated with, maintained, authorized, endorsed or sponsored by Weber Grills. Thanks that is very helpful. I can't help with your question, but as someone who is looking to purchase a pellet grill in the coming weeks, is glow plug failure a common problem with the SF? Thread starter NewUser; Start date Dec 28, 2020; Dec 28, 2020 #1 N. NewUser New member. I'll take that! You must log in or register to reply here. Log in or sign up to leave a comment Log In Sign Up. Very easy to change in less than 10 minutes. You are using an out of date browser. Remove the glow plug from the glow plug assembly by pulling it out and away. Properly Installed Glow Plug. 7 out of 18 found this helpful. card classic compact. Remove the glow plug from the glow plug assembly by pulling it out … I take it you bought yours assembled already? Smoke fire won’t maintain temp. I … Hopefully the new model glow plug will solve my problem. Anyway probably won't be able to install and test until Friday but will report back as soon as I can. All of this helps to prevent the chance of auger jams, back burn into the hopper and barbecue fires … Install the replacement glow plug into the glow plug assembly by firmly pushing it into … The implicit promise is that the grill works properly and as advertised. r/smokefire: Sub-reddit dedicated to Weber smokefire series pellet cookers. The first thing I was told was the software would be updated to fix the “E6 error” in April. Weber Talk . Maybe a bad bunch of glow plugs. best. They also promised very even heat, that grease would drain completely out of the grill, and that the vast majority of ash would fall into the ash catcher below the grill. Glad I posted the pics and I told you I didn't have a clue how it works. JavaScript is disabled. I received a new glow plug today and while I was supposed to receive 2 I'm thrilled to get 1 after waiting 3 weeks.